Question What is the particle size of your sodium chloride products?  I do not see this information on the Product Specification sheet or Certificate of Analysis.
Answer

Particle size may not be part of the product specifications and may not be routinely tested by Avantor Performance Materials. However, we expect the particle size distribution properties to be as per the table below for the following Avantor Performance Materials products:


Granular Sodium Chloride Products:

Macron 7532 Sodium Chloride, Granular USP-FCC
Macron 4577 Sodium Chloride, Granular USP-FCC
Macron 7544 Sodium Chloride, Granular CP
Macron 7713 Sodium Chloride, Granular USP-GenAR®
Macron 7581 Sodium Chloride, Crystal, AR® (ACS)
J.T.Baker 3627 Sodium Chloride, Granular USP, Multi-Compendial
J.T.Baker 3628 Sodium Chloride, Granular USP-FCC
J.T.Baker 3629 Sodium Chloride, Granular USP-FCC
J.T.Baker 3624 Sodium Chloride, Crystal, BAKER ANALYZED® ACS Reagent

Table 1138a. Granular NaCl Particle Size

Typical Properties    
U.S.S. Mesh Sieve Opening (micron) % Retained
20 840 Trace
30 600 2
40 425 32
50 300 46
70 210 17
Pan - 3

Powder Sodium Chloride Products:

Macron 7540 Sodium Chloride Powder, USP-GenAR®
Table 1138b. Powder NaCl Particle Size

Typical Properties    
U.S.S. Mesh Sieve Opening (micron) % Retained
20 840 0%
80 177 30-50%